AIR-CELL Permishield

3-In-1 Insulation, Thermal Break And Vapour-Permeable Sarking

 

 
Handling and Storage

Kingspan AIR-CELL® Insulation products must be transported in its protective packaging and kept clean and dry. Standing rolls on end reduces risk of damage should moisture be present in the packaging. Surfaces must be kept free of contaminants such as dust and grease, and must not be stored with foil surfaces in contact with alkaline materials i.e. wet cement, lime, etc.

Important Information
These instructions are guidelines only and should be interpreted with consideration for the specification building design. This installation of Kingspan AIR-CELL® should be in conformance with the applicable clauses for AS 3999 and AS/NZS 4200.2 unless otherwise specified.
Kingspan AIR-CELL® can be damaged by intense heat above 105°C and contact with sparks and flame from blow torches, welders, cutting tools, etc. must be avoided.
The installer must make due provision for safety when installing Kingspan AIR-CELL® in any application
Cladded Wall, Stud Frame
Counter Batten Method


  1. Roll out Kingspan AIR-CELL® horizontally and fix to outside of frame.
  2. Cut Kingspan AIR-CELL® carefully around doors, windows and other openings, so that it neatly abuts to frames.
  3. Butt join Kingspan AIR-CELL® sheets and tape with a 48 mm wide reinforced foil tape.
  4. Fix counter battens and exterior cladding.
Download the cladded wall, stud frame installation instructions 
Steel-framed Wall


  1. Fix Kingspan AIR-CELL® loosely to the outside of frame leaving flexibility for Kingspan AIR-CELL® to be dished onto the wall cavity.
  2. Cut Kingspan AIR-CELL® carefully around doors, windows and other openings, so that it neatly abuts to frames.
  3. Butt join Kingspan AIR-CELL® sheets and tape with a 48 mm wide reinforced foil tape.
  4. Provide for outer air space by adhering the Kingspan AIR-CELL® Spacer Biscuits™ to the outer face of the Kingspan AIR-CELL® (approximately three (3) Spacer Biscuits™ per square metre required).
  5. Commence installing cladding in accordance with manufacturer's installation instructions..
Download the steel-framed wall installation instructions

Advisory Note: Fibre-cement Cladded Walls
If fibre-cement cladding products are used, the cladding should be fixed by screwing through the Kingspan AIR-CELL Permishield® to the steel frame. Even pressure should be applied to ensure that the upper board overlap is in full contact with the lower board. If gaps occur, close using brad nails.
Care must be taken that the screw gun torque and depth settings are appropriate to apply even pressure on the Kingspan AIR-CELL Permishield® without over-stressing the cladding material, particularly when installing cladding less than 12 mm thick that does not fit flat to the frame. Kingspan AIR-CELL Permishield® 65 should be used when this is the case.
For installations with fibre-cement claddings that are less than 12 mm in thickness the Counter-batten Method is the preferred method.


Counter-batten Method:




  1. Roll out Kingspan AIR-CELL® horizontally and fix to outside of frame.
  2. Cut Kingspan AIR-CELL® carefully around doors, windows and other openings, so that it neatly abuts to frames.
  3. Butt join Kingspan AIR-CELL® sheets and tape with a 48mm wide reinforced foil tape.
  4. Fix counter battens and exterior cladding.

Reverse Brick Veneer Wall
Counter Batten Method
  1. Roll out Kingspan AIR-CELL® horizontally and fix to batten.
  2. Cut Kingspan AIR-CELL® carefully around doors, windows and other openings, so that it neatly abuts to frames.
  3. Butt join Kingspan AIR-CELL® sheets and tape with a 48 mm wide reinforced foil tape.
  4. Fix counter battens and exterior cladding.